SANTEST CO.,LTD.

List with applicationsList with models

Model GY Series

GYSE-A-FX6 Probe
Flexible rod type analogue output
GYSE-A-FX6 Probe

Special probe for not linear but curve application. The material of the probe rod is PTFE, the rod parts can be bent (Min. R is 180mm). In case of long stroke, bending the rod and putting in a compact box is possible for transportation.

Specifications

Non-linearity≦±0.025%FS TYP
Resolution16bit(1/65536)
Repeatability≦±0.001%FS (Min. ±3μm)
Position
(STD)
0-10V(output current : Max.5mA, load : Min.2kΩ)
or 4-20mA(load : Max.500Ω)
Velocity
(Option)
±10V or 4-20mA
Resolution:16bit(1/65536)
AlarmOpen drain 50V 0.1A (for lost magnet)
Power supply+24(±2)VDC (70mA)
Sampling freq.Std 1kHz(up to stroke 1000mm)
Max. Pressure5MPa(probe rod)
Operating temp.0°C-+65°C
Storage temp.-20°C-+65°C
Vibration3G(or 40Hz 1mmPP)
Shock10G(2msec)
IP gradeIP67 (probe head)

・The above mentioned accuracy applies to sensors with an

effective stroke of 300 mm or more.

Model No.

①Effective stroke
  15-7500mm

②Thread dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)

③Tip dead zone
  S:70mm/90mm/100mm(STD)
  ・S (STD length) depends on the selected magnet or float in ⑤.

tip DZmagnetfloat
70mmM2PN, M0SM, M0LM,
M3, M11N
F25N, F28N
90mm F28S, F30S
100mmT144, T163F40S, F42S, F50S
□:□mm(option)(specified by customers)

④Thread/Rod diameter
  N-FX6:M18xP1.5, flexible rod Φ6

⑤Associated magnet or float

magnetfloat
M0SM :No.ΦSPM
M0LM :No.ΦLPM
M3 :No.3
M2PN :No.2PN (STD)
M11N :No.11N
T144 :No.T14-M4
T163 :No.T16-M3
MG□ :other magnet
F30S :Φ30 SS316L
F28S :Φ28 SS316
F42S :Φ42.5 SS316
F40S :Φ40 SS316(B)
F54S :Φ54 SS304
F50S :Φ50 SS316
F28N :RF-A6 plastic
F25N :RF-A10 plastic
FL□ :other float

⑥Cable connection
  CN:connector(STD)
  △G□F:pigtail / cable end : free
  △G□A:pigtail / cable end : with connector for relay
  (□:cable length(m))
  (△:cable type
  S:standard, H:high temp. cable, R:robot cable)

⑦Position output(OUT1)
  AD:0-10V(When magnet moves toward tip, output increase)
  AR:10-0V(When magnet moves toward tip, output decrease)
  BD:4-20mA(When magnet moves toward tip, output increase)
  BR:20-4mA(When magnet moves toward tip, output decrease)
  CD□□:bipolar output(-□V-+□V)
  (for example CD10:-10V-+10V)
  CR□□:bipolar output(+□V--□V)
  (for example CR05:+5V--5V)
  V Z/F:option (specified voltage)
  (for example V1/5:1-5V, V9.5/0.5:9.5-0.5V)
  I Z/F:option (specified current)
  (for example I5.2/20:5.2-20mA, I18/5:18-5mA)
  Ordering loose connector only.

⑧Option : Analogue output(OUT2)
  ・N:without option(STD)
  ・position output:select from ⑦
  ・Velocity output(Note1)
  VA[ ]:±10V
  WB[ ]:4-20mA
  [ ]:max. velocity(1.00-999 mm/s)
  

  (Note1)
  VA : When magnet stops, output is 0V.
  When moving toward probe tip, +10V.
  WB : When magnet stops, output is 4mA.
  When moving in any direction, 20mA.
  S:straight
  L:L-shaped
  For GYSE connector, we recommend to purchase our cable with connector since a special clamp tool is necessary to mount the connector at cable end.
  CN-LM-0-□
  【Z=output at zero position, F=output at full position】

Dimensions

Probe Connector type(straight)(STD) Connection 
Zoom ZoomZoom
  • Catalogue
Pagetop

Contact Form

Pagetop