EX-GYdS-A probe is a level or displacement transducer of the
flameproof enclosure type which has GYcAT circuit inside.
An explosion protection symbol is Exd II CT6, and you can use it in the
most of the explosive gas atmosphere.
Form official approval pass symbol :
No. TC14614 (rod diameter Φ10),
No. TC14615 (rod diameter Φ13.8)
・ Noise cancellation
( Created on Feb. 7. 2023 )
Non-linearity | ≦±0.05%FS (Typ.) |
---|---|
Resolution | ≦0.01%FS |
Repeatability | ≦±0.01%FS |
Temp. drift | ≦±40ppmFS / °C |
Voltage output | 0〜10V or 10〜0V ( output current :Max.5mA, load :Min.2kΩ ) |
Current output | 4〜20mA or 20〜4mA ( load :Max.500Ω ) |
Alarm | Open collector 30V 0.1A |
Power supply | +24(±2)VDC ( 50mA ) |
Sampling freq. | Std. 1kHz ( Total rod length : 1300mm ) |
Max. Pressure | 35MPa ( probe rod ) |
Operating temp. | -20°C〜+60°C |
Storage temp. | -40°C〜+80°C |
Vibration | 6G ( or 40Hz 2mmPP ) |
Shock | 50G ( 2msec ) |
IP grade | IP65 |
Explosion -proof symbol | ExⅡ CT6 |
・The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
The specification of stroke less than 300mm is equal that of stroke 300mm.
① Rod diameter
10 :Φ10
14 :Φ13.8
② Total rod length
□ :□mm
(Total rod length = head dead zone + effective stroke + tip dead zone)
③ Effective stroke
15mm〜3500mm
④ Head dead zone
50 :50mm(Std.)
□ :□mm(option)(specified by customers)
・Possible Min. length depends on the selected magnet or float.
tip DZ | magnet | float |
---|---|---|
70mm | BF | |
100mm | T142,T162 | F40S,F42S,F50S,F54S |
□ :□mm(option)(specified by customers)
・Possible Min. length depends on the selected magnet or float.
magnet | float |
---|---|
T142 :No.T14-M2 T162 :No.T16-M2 BF : No.2SI3-14 | F40S :Φ40 SS316(B) F42S :Φ43 SS316L F50S :Φ50 SS316L F54S :Φ54 SS304 |
⑦ Cable diameter
10 :Φ8〜Φ10
12 :Φ10〜Φ12
⑧Position output
AD :0〜10V(When magnet moves toward tip, output increase.)
AR :10〜0V(When magnet moves toward tip, output decrease.)
BD :4〜20mA(When magnet moves toward tip, output increase.)
BR :20〜4mA(When magnet moves toward tip, output decrease.)
Probe | Probe head opener | |||||
---|---|---|---|---|---|---|