| Non-linearity | < ±0.1%FS TYP |
|---|---|
| Resolution | < 0.01%FS |
| Repeatability | < ±0.05%FS |
| Temp drift | 22μm/°C+50ppmFS/°C (probe) / ±50ppmFS/°C (controller) |
| Voltage output | 0-10V or 10-0V / (output current:Max.5mA, load:Min.2kΩ) |
| Current output | 4-20mA or 20-4mA / (load:Min.500Ω) |
| Power supply | +24 (±2) VDC (100mA) |
| Frequency response | Std 1kHz (depending on stroke) sampling |
| Admissible press. | 35MPa (probe rod) |
| Operating Temp | -5°C-+100°C(probe) / 0°C-+60°C(controller) |
| Storage Temp | -40°C-+120°C(probe) |
| Vibration | 6G (or 40Hz 2mmPP) |
| Shock | 50G (2msec) |
| Protection | IP64 (probe) |
| Cable length | 1.5m (Standard) (Option Max.100m) |
The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
Zero/Gain adjustments by trimmer of controller is possible, std within ±3%FS.

(1):Effective stroke
15mm-2000mm
(2):Sensor rod
diameter
8:Φ8 (Standard)
blank:Φ10
(3):Cable length (m)
Standard:1.5m
*In case of an effective stroke of 1000mm or more,
it needs screw side dead zone length of 120mm and
tip dead zone length of 120mm.

(1):Output
A:0-10V
B:4-20mA
C:others (bipolar)
(2):Efective stroke
15mm-2000mm
(3):Direction of output
(toward probe tip)
D:output increase
R:output decrease
| Probe | Controller | |||||
|---|---|---|---|---|---|---|
Material probe head:SS304, probe rod:SS304
Standard magnet:T14-M2. Other magnets are available from Magnet Grouping [B].
The tip dead zone length (100mm) depends on the magnet or float type.