| Resolution (position output) | 16bit (1/65536) (Probe:GYcRS, GYMR5, GYFRS) / 0.01%FS (Probe:GYGS, GYPM, GYHR, GYcRP) |
|---|---|
| Temp drift | ±10ppmFS/°C |
| Position output (OUT1) (OUT2:Option) | 0-10V (output current:Max.5mA, load:Min.2kΩ) or 4-20mA (load:Min.500Ω) |
| Velocity output OUT2 (Option) | ±10V or 4-20mA |
| Alarm output | Open collector 0.1A 30VDC (Cable disconnection and magnet drop) |
| Power supply | Standard:+24VDC±5% ( < 150mA) / Option:+15VDC±5% ( < 250mA) (Note1) |
| Frequency resp. | Std 1kHz (depending on stroke) sampling |
| Operating Temp | 0°C-+65°C |
| Storage Temp | -20°C-+85°C |
The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
(Note1)This option is limited depending on probe type and effective stroke.

(1):Probe
RS:GYcRS probe
RP:GYcRP probe
R5:GYMR5 probe
FS:GYFRS probe
GS:GYGS probe
PM:GYPM probe
HR:GYHR probe
(2):Effective stroke (mm)
(3):Dead zone length of probe head side (mm)
(4):Analogue Position Output (OUT1)
| AD | 0-10V (Std) |
| AR | 10-0V |
| BD | 4-20mA |
| BR | 20-4mA |
| CD or CR□□ (bipolar output) [ex] CD10 CR05 | □□V-□□V -10V-+10V +5V--5V |
| V Z/F [ex] V1/5 V9.5/0.5 | custom order 1-5V 9.5-0.5V |
| I Z/F [ex] I5.12/20 I20/5.38 | custom order 5.12-20mA 20-5.38mA |
(5):Option:Analogue output (OUT2)
Position:see (4)
Velocity (Note2)
VA[ ] ±10V [ ]:max velocity
WB[ ] 4-20mA (1.00-999mm/sec)
N:No option (ex.9R99:max velocity=9.99mm/sec)
(6):Power supply
24S:+24VDC (Standard)
15S:+15VDC (Option)
(7):Magnet and Float
| Magnet | Float |
|---|---|
| M0:No.Φ magnet M0SM:No.ΦSPM magnet M0LM:No.ΦLPM magnet M2P:No.2P magnet M2PN:No.2PN magnet M3:No.3 magnet M11:No.11 magnet M11N:No.11N magnet T142:No.T14-M2 magnet T144:No.T14-M4 magnet T162:No.T16-M2 magnet T163:No.T16-M3 magnet MG□:other magnet | F28S:Φ28SS316 float F30S:Φ30SS316 float F40S:Φ40SS316 (B) float F42S:Φ42.5SS316 float F50S:Φ50SS316 float F54S:Φ54SS304 float F25N:RF-A10 plastic float F28N:RF-A6 plastic float FL□:other float |
(Note2)
VA:When magnet stops, output is 0V. When moving toward probe tip, +10V.
WB:When magnet stops, output is 4mA. When moving in any direction, 20mA.