SANTEST CO.,LTD.

List with applicationsList with models

Model GY Series

GYDC-05 Controller
High accuracy digital output
(Parallel、SSI、A/B pulse)
GYDC-05 Controller

GYDC-05 controller enables digital output of 1μm resolution and also analogue output.
Other features are as options, -Additional analogue output of magnet velocity -SSI output and incremental output GYDC-05 controller can be used with:GYcRS/GYMR5/GYFRS/GYGS/GYPM/GYHR/GYcRP probes.

Specifications

Position
(digital)(24bit)
Parallel, Binary code(*1), Tr On=「1」
(option:SSI or A/B incremental output)
Resolution
(digital)
Probe:GYSE-R, GYcRS, GYMR5, GYFRS
STD 0.01mm(Min. 0.001mm)
Probe:GYGS, MS, PM, HR, cRP, KM
STD 0.1mm
Position(OUT1)
(analogue)
0-10V(Max.5mA, Min.2kΩ)
or 4-20mA(load:Max.500Ω)
Resolution
(analogue)
Probe:GYSE-R, GYcRS, GYMR5, GYFRS
 16bit(1/65536)
Probe:GYGS, MS, PM, HR, cRP, KM
≦0.01%FS
Velocity
(OUT2)
Option
±10V or 4-20mA
Alarm(*2)Open collector 0.1A 30VDC(*2)
Power supply+24VDC±5%(≦160mA)
Sampling freq.Std 1kHz(up to stroke 1000mm)
Temp. drift≦±10ppmFS/°C
Operating temp.0°C-+65°C
Storage temp.-20°C-+75°C

・The above mentioned accuracy applies to sensors with an
effective stroke of 300 mm or more.
(*1)can be changed to Gray code at user side
(*2)Cable disconnection and magnet drop

Model No.

①Digital output
  1:Standard, parallel output
  2100:with A/B incremental(pulse freq.:1MHz)
  2200:with A/B incremental(pulse freq.:500kHz)
     (standard for resolution D7 or D8)
  2300:with A/B incremental(pulse freq.:250kHz)
     (standard for resolution D2-D5)
  2400:with A/B incremental(pulse freq.:125kHz)
  2600:with A/B incremental(pulse freq.:31kHz)
  2700:with A/B incremental(pulse freq.:15kHz)
  005A:with SSI output
  005S:with SSI output : External sync.
  ・In case of A/B incremental, Max. magnet speed is limited with the selected resolution and pulse freq.
  For standard setting, the speed is as below.

Resolution(mm)Pulse freq.Max. magnet speed
0.1250kHz15m/sec
0.05250kHz15m/sec
0.01250kHz8m/sec
0.005250kHz4m/sec
0.002500kHz3.2m/sec
0.001500kHz1.6m/sec

②Resolution
  D2:0.1mm
  D3:0.05mm ・probe:GYSE-R, GYcRS, GYMR5, GYFRS, D4 is STD.
  D4:0.01mm ・probe:GYGS, GYMS, GYPM, GYcRP, GYHR, GYKM, only D2 is available.
  D5:0.005mm
  D7:0.002mm
  D8:0.001mm

③Direction of output
  D:output data increase toward probe tip
  R:output data decrease toward probe tip

④Probe
  SR:GYSE-R
  RS:GYcRS
  R5:GYMR5
  FS:GYFRS
  HR:GYHR
  GS:GYGS
  PM:GYPM
  RP:GYcRP
  MS:GYMS
  PR:GYPMR
  P2:GYPE2K
  KM:GYKM
  KRS:GYKM-RS

⑤Effective stroke(mm)

⑥Thread dead zone
  S:50mm(STD)
  □:□mm(option)(specified by customers)

⑦Associated magnet or float

magnetfloat
M2P :No.2P (STD)
M0SM :No.ΦSPM
MG0 :No.Φ
M0LM :No.ΦLPM
M3 :No.3
M2PN :No.2PN
M11N :No.11N
M11 :No.11
T144 :No.T14-M4
T142 :No.T14-M2
T163 :No.T16-M3
T162 :No.T16-M2
MG□ :other magnet
F30S :Φ30 SS316L
F28S :Φ28 SS316
F42S :Φ42.5 SS316
F40S :Φ40 SS316(B)
F54S :Φ54 SS304
F50S :Φ50 SS316
F28N :RF-A6 plastic
F25N :RF-A10 plastic
FL□ :other float

⑧Position output(OUT1)
  AD:0-10V(When magnet moves toward tip, output increase)
  AR:10-0V(When magnet moves toward tip, output decrease)
  BD:4-20mA(When magnet moves toward tip, output increase)
  BR:20-4mA(When magnet moves toward tip, output decrease)
  CD□□:bipolar output(-□V-+□V)
      (for example CD10:-10V-+10V)
  CR□□:bipolar output(+□V--□V)
      (for example CR05:+5V--5V)
  V Z/F:option (specified voltage)
      (for example V1/5:1-5V, V9.5/0.5:9.5-0.5V)
  I Z/F:option (specified current)
      (for example I5.2/20:5.2-20mA, I18/5:18-5mA)
  【Z=output at zero position, F=output at full position】

⑨additional analogue output(OUT2)
  ・N:without option(STD)
  ・position output:select from ⑤
  ・velocity output(Note1)
  VA[  ]:±10V
  WB[  ]:4-20mA
  [  ]:max velocity (1.00-999mm/sec)
  (ex.9R99: max velocity=9.99mm/sec)
  (Note1)
  VA:When magnet stops, output is 0V.
  When moving toward probe tip, +10V.
  WB:When magnet stops, output is 4mA.
  When moving in any direction, 20mA

⑩Option
  2ME:2 magnets, each magnet position
  2MR:2 magnets, relative distance between 2pcs(OUT1)
  X2:higher sampling freq. double
  X3:higher sampling freq. triple
  X4:higher sampling freq. qaudruple (3.75kHz)
  <For higher sampling option>
  ・probe tip DZ needs extra 30mm
  ・for example, stroke : 500mm, standard is 1kHz and with X2 option, it is 2kHz.

Dimensions

Controller Wiring  
Zoom Zoom
  • Catalogue
Pagetop

Contact Form