| Non-linearity | < ±0.025%FS TYP |
|---|---|
| Resolution (anaoglue) (digital) | 16bit (with GYHC) / Min.1μm (with DC05) |
| Repeatability | < ±0.01%FS |
| Temp drift | < ±20ppmFS/°C |
| Admissible press. | 35MPa (probe rod) |
| Operating Temp | -20°C-+80°C |
| Storage Temp | -40°C-+80°C |
| Vibration | 6G (40Hz2mmPP) |
| Shock | 100G (2msec) |
| Protection | IP65 |
| Cable length | 1.5m (Standard) (Option Max.200m) |
The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.
Resolution depends on the controller combined.

(1):Effective stroke
15mm-5200mm
(2):Thread
M:M24xP1.0 (Std)
N:M18xP1.5
U:3/4-16UNF
(3):Sensor rod diameter
blank:Φ10 (Standard)
8:Φ8
14:Φ13.8
(4):Cable connection
CN:Connector (Standard)
G*:Pigtail type
(*:Cable length [m], Standard:1.5m)
Combined controller
Analogue output type:GYHC, GYFC2
Digital output type:GYDC-05
With LED Display:GKS-01 (only GYcRS)
| Connector type (Standard) | Pigtail type (Option) | |||||
|---|---|---|---|---|---|---|
Material probe head:Al diecast, probe rod:SS304
(GYcRP probe) Standard magnet:No.2P Other magnets are available from Magnet Grouping [B].
(GYcRS probe) Standard magnet:No.2PN Other magnets are available from Magnet Grouping [GG].
The tip dead zone length (70mm) depends on the magnet or float type.
Connector:Sanwa SNW-1607-PCF (Material:zinc alloy fluoroplastic)
In case of using probe only,
probe outputs digital signals (start/stop) using RS422 differential
line drivers. In response to user's interrogation (start) pulse, probe
provides stop pulse.