SANTEST CO.,LTD.

List with applicationsList with models

Model GY Series

GYcAT Probe
Performing・All-in-one
GYcAT Probe
Thanks to the Surface Mount Technology, the entire signal
processing electronics of GYcAT series is integrated into a
transducer head.
You can get a voltage or current analog signal proportional to a
magnet position only by applying a 24V dc power supply directly to
the transducer.
GYcAT series have alarm output and head is equipped with noise
cancellation functions.

Specifications

Non-linearity< ±0.05%FS TYP
Resolution< 0.01%FS
Repeatability< ±0.01%FS
Temp drift40ppm FS/°C
Voltage output0-10V or 10-0V / (output current:Max.5mA, load:Min.2kΩ)
Current output4-20m or 20-4mA / (load:Min.500Ω)
Alarm outputOpen collector 30V 0.1A
Power supply+24 (±2) VDC (100mA)
Frequency responseStd 1kHz (depending on stroke) sampling
Admissible press.35MPa (probe rod)
Operating Temp-20°C-+65°C
Storage Temp-40°C-+80°C
Vibration6G (or 40Hz 2mmPP)
Shock50G (2msec)
ProtectionIP65

The above mentioned accuracy applies to sensors with an effective stroke of 300mm or more.

Model No.

(1):Effective Stroke
15mm-2500mm

(2):Output
A:0-10V
B:4-20mA
C:others (bipolar etc)

(3):Direction of output
(toward probe tip)
D:output data increase
R:output data decrease

(4):Thread
M:M24xP1.0 (Standard)
N:M18xP1.5
U:3/4-16UNF

(5):Sensor rod diameter
blank:Φ10 (Standard)
8:Φ8
14:Φ13.8

(6):Cable connection
CN:Connector (Standard)
G*:Pigtail type
(*:Cable length [m], Standard:1.5m)
Connector:straight type
Connector:only counter connector is supplied. In case cable needed,specify cable length.

Dimensions

Connector type (Standard) Pigtail type (Option)  
Zoom Zoom

Material probe head:Al diecast, probe rod:SS304
Standard magnet:No.2P. Other magnets are available from Magnet Grouping [B].
The tip dead zone length (70mm) depends on the magnet or float type.
The length of the cable should be less than 10m in case of using the voltage output type
and 100m in case of using the current output type.
Connector:Sanwa SNW-1607-PCF (Material:zinc alloy fluoroplastic)
Applied cable diameter:Φ6.6-Φ7.5
Wire size:Less than 0.5mm2

Connection
1 DC24V
2 NC
3 0V
4 SIG COM
5 Voltage output
6 (Current output)
7 Alarm output
*Shield should be connected with 0V at user side.

  • Catalogue
Pagetop