HOME お問い合わせ
Company Profile Products Trade Division Contact Us
Products
Magnetostrictive Displacement Transducer

GYcAT(Analog Transducer)
GYcAT Image -Low cost,all-in one,direct analog output.
(4-20mA or 0-10V)

-Absolute,non-contacting transducer.

-Improved non-linearity,inproved S/N ratio, reduced power consumption.

-Easy to connection.(Screw type)

-Wide temperature operating range.

-Shock and vibration resistant.

??
Accuracy Non-linearity ±0.025%FS TYP.
Resolution <0.01%FS
Repeatability <±0.01%FS
Temprature drift <40ppm FS/C
Output signal GYLT 4-20mA(max.500Ohm)
GYLS 0-10V(max.5mA,min.2kOhm)
Frequency Response sampling 1kHz standard
Power supply +24VDC±2V 0.05A
Environment Admissible pressure 35MPa
Operating temperature -20C...+80C
Storage temperature -40C...+80C
Vibration 6G(or 40Hz 2mmpp)
Shock 50G(2msec)
Protection Class IP67(10kPa,30min)
*Specification are applicable over 300mm stroke.
??
????
GYcAT-????-??-?-?
1 Stroke (mm)
max. 3000mm
2 Direction output
D:Forward
R:Reverse
2 Thread
M-M24XP1.0(Standard)
N-M18XP1.5
U-3/4-16UNF
?????

GYLT/LS probe
probe head ... Al diecast
probe rod ... SS304
GYcAT Dimensions
PIN#

Function

1 DC24V
2 0V
3 Current
or
Voltage
Output
4 COM
*shield to be connected to 0V at user side.
 